Pressure tester correct operation method

Voltage resistance tester is a relatively common power detection instrument, which has a certain application in many fields. We need to pay special attention when using a voltage tester. If you do not pay attention, it is easily accessible. Here's to talk about the correct use of pressure tester:
1) Turn on the power: Make sure the “Voltage adjustment” knob is set to “0”, then turn on the power switch.
2) Set the "leakage current" value: Press the "15" switch to adjust the "leakage current preset" potentiometer "14" to preset the "leakage current" at the desired value.
3) Connect the DUT: According to the needs of the DUT, connect the test line to the DUT.
4) "Timed test": Set the timer switch "17" in the "timing" position, adjust the timing dial switch, set the desired timing time, then press the "start" switch, and adjust the "voltage adjustment" knob Output voltage to the desired value.
5) "Manual test": Set the timer switch "18" to the "manual" position and press the "start" switch.
6) During the test, if the detected "leakage current" value exceeds the preset "leakage current" preset value, the instrument will automatically alarm and cut off the output voltage. Just press the "reset" switch at this time, the instrument will return to the state to be tested. (If external leakage test is used, release the start switch on the test stick to continue the test.)
7) If the detected "leakage current" does not exceed the set value, the instrument will return to the state to be tested after the timer expires or the "reset" switch is pressed.
8) Remote control test: Insert the five-pin plug of the remote control test into the socket on the instrument and press the switch on the test rod to perform the test. Note: When using the remote test stick test, the timing function of the instrument is invalid.

Shanghai Miyuan Electric Co., Ltd. produces and sells the following products: ZGF DC high voltage generator, high voltage voice phasor, DC resistance tester, battery load tester, loop resistance tester, microcomputer relay protection tester, grounding resistance Tester, high-voltage wireless nuclear phase analyzer, high-voltage test transformer, DC single-arm double bridge, DC high-voltage generator, tubular electric heater, dielectric oil dielectric strength tester, watch-type near-electricity alarm, zinc oxide arrester tester , Insulation Resistance Tester, High Voltage Megaohmmeter, High Voltage Insulation Mat, Short Circuit Grounding Cable; Portable Dynamic Balance Measuring Instrument, On-the-Spot Dynamic Balance Measuring Instrument, Long Range Infrared Thermometer, High Voltage Insulation Mat in Distribution Room, Transformer Loss Parameter Intelligent Test Instrument, insulation boots gloves pressure test device, transformer characteristics integrated test bench, tie rod flow meter, ultra high voltage withstand tester, three-phase multi-phase volt ammeter, intelligent dielectric loss tester, intelligent loop resistance tester, Lightning counter calibrator, transformer on-load switch parameter tester, mine cable fault detector, zinc oxide arrester detector, dip In-line tubular electric heater, DC resistance meter, digital ground resistance meter, portable digital vibration meter, infrared thermometer, frequency conversion series resonant test device, high current generator, vacuum oil filter manufacturer, voltage resistance tester, Wireless high-voltage nuclear phase meter and so on.