Kha-220 Full-Auto Biochemistry Analyzer
120tests / hour                   30 sample positions
60 reagent positions            81 reaction positions  Â
Â
Technical Feature  Â
                                                  Â
Performance
Type: Discrete Automatic
Principle: Absorption Spectrometry, Turbidimetry
Throughput: Constant 120tests/hour (without ISE)
Test Method: End-point, Fixed-time, kinetic
            Support dual reagents/double wavelength
Test sequence: Run tests in strict accordance with sample sequence,
              Insert emergency at any time
Online Sample: 30 samples/ batch, unlimited batch input
Reaction Time: Max 15minutes
Reaction Volume: Mini 150μl
Cuvette: 81 cuvettes
Optical System
Light Source: Halogen-tungsten lamp, 12V/20W
More than 2000hrs service time
Spectrometric Method: After spectrometric method
Wavelength: 8 wavelengths, selectable among 340-800nm
Absorption Range: 0-4.0Abs
Optical System: Integrated full closed optical system
Sample system
Sample Tray: 30 positions
Sample Volume: 2-100μl, 0.1μl by step,
Sample Probe: Liquid level detection, anti-collision protection and inventory checking,
              have automatic stop and alarm prompt for an obstacle
Probe Cleaning: Automatic washing for both interior and exterior
Others
Water Consumption: less than 3L/hour
Power Supply: AC 220 ±22V   50HZ ±1HZ
Power: Max 200VA
Ambient Temperature: 10°C-30°C
Reagent System
Reagent Volume: 20-500μl, 1μl by step
Reagent Tray: 60 positions, open system
Reagent Probe: : Liquid level detection, anti-collision protection and inventory checking,
               have automatic stop and alarm prompt for an obstacle
Probe Cleaning: Automatic washing for both interior and exterior
Reagent Bottle: Bottles with 15ml,20ml,30ml,50ml,70ml are available
dead volume <1ml
Temperature Control System
Heating Mode: Solid constant temperature closed direct heating
Equilibrium Time: less than 3minutes
Reaction Temperature: 37±0.2°C
Temperature Fluctuation: ± 0.2°C
Control and Calibration
Calibration Mode: Linear, Logit-4p, Logit-5p, Spline, Factor, Polynomial
             Automatically check calibration curve and select the calibration type with the best fitting
QC Type: Real time QC, QC in one day, QC between days;
            QC chart: L-J, Cumulative, Twin Plot
QC Rules: Multi-rule; default: Westguard
Status Monitoring: Real -time monitor the sample tray, reagent tray, reaction tray, reaction cup, lamp, purified water; Real-time display reaction tray humidity, reagent remain, reaction curve, calibration curve and QC chart.
Inspection and Judgment: Reaction end point judgment, reaction linear range judgment, substrate depletion judgment, front belt detection,reaction limit inspection, reagent blank absorbance judgment
Operation Unit
Operation System:Â Â Windows operation system
Database: SQL Server
Data Storage: Automatic storage and backup, permanently preserve all kinds of data
Print Content: Print content can be customized
Print Format: Provide a variety of print format
Â
 KHA-220 Full-auto Biochemistry Analyzer
120tests / hour                   30 sample positions
60 reagent positions            81 reaction positions  Â
Â
Technical Feature  Â
                                                  Â
Performance
Type: Discrete Automatic
Principle: Absorption Spectrometry, Turbidimetry
Throughput: Constant 120tests/hour (without ISE)
Test Method: End-point, Fixed-time, kinetic
            Support dual reagents/double wavelength
Test sequence: Run tests in strict accordance with sample sequence,
              Insert emergency at any time
Online Sample: 30 samples/ batch, unlimited batch input
Reaction Time: Max 15minutes
Reaction Volume: Mini 150μl
Cuvette: 81 cuvettes
Optical System
Light Source: Halogen-tungsten lamp, 12V/20W
More than 2000hrs service time
Spectrometric Method: After spectrometric method
Wavelength: 8 wavelengths, selectable among 340-800nm
Absorption Range: 0-4.0Abs
Optical System: Integrated full closed optical system
Sample system
Sample Tray: 30 positions
Sample Volume: 2-100μl, 0.1μl by step,
Sample Probe: Liquid level detection, anti-collision protection and inventory checking,
              have automatic stop and alarm prompt for an obstacle
Probe Cleaning: Automatic washing for both interior and exterior
Others
Water Consumption: less than 3L/hour
Power Supply: AC 220 ±22V   50HZ ±1HZ
Power: Max 200VA
Ambient Temperature: 10°C-30°C
Reagent System
Reagent Volume: 20-500μl, 1μl by step
Reagent Tray: 60 positions, open system
Reagent Probe: : Liquid level detection, anti-collision protection and inventory checking,
               have automatic stop and alarm prompt for an obstacle
Probe Cleaning: Automatic washing for both interior and exterior
Reagent Bottle: Bottles with 15ml,20ml,30ml,50ml,70ml are available
dead volume <1ml
Temperature Control System
Heating Mode: Solid constant temperature closed direct heating
Equilibrium Time: less than 3minutes
Reaction Temperature: 37±0.2°C
Temperature Fluctuation: ± 0.2°C
Control and Calibration
Calibration Mode: Linear, Logit-4p, Logit-5p, Spline, Factor, Polynomial
             Automatically check calibration curve and select the calibration type with the best fitting
QC Type: Real time QC, QC in one day, QC between days;
            QC chart: L-J, Cumulative, Twin Plot
QC Rules: Multi-rule; default: Westguard
Status Monitoring: Real -time monitor the sample tray, reagent tray, reaction tray, reaction cup, lamp, purified water; Real-time display reaction tray humidity, reagent remain, reaction curve, calibration curve and QC chart.
Inspection and Judgment: Reaction end point judgment, reaction linear range judgment, substrate depletion judgment, front belt detection,reaction limit inspection, reagent blank absorbance judgment
Operation Unit
Operation System:Â Â Windows operation system
Database: SQL Server
Da
Clutch kit includes Clutch Cover, Clutch Disc and clutch release bearing.
SYC Clutch has developed SET / KIT products for years, in order to provide various benefits for our customers.
Function of the Clutch
- Function of transmitting the torque from the engine to the drivetrain.
- Smoothly deliver the power from the engine to enable smooth vehicle movement.
- Perform quietly and to reduce drive-related vibration.
- Protect the drivetrain when given the inappropriate use. Given the situation, the SYC clutch will fail when given the inappropriate use in turn to protect the rest of the drivetrain, similar to the function of an electric fuse.
Why replace the clutch as clutch kit?
1. Improve durability. Reduce the cost of after sales.
2. Better profit for All. Clutch Set / Clutch Kit product is expected to be more profitable for both distributors and drivers. Distributors can secure more sales by selling 3 components at a time while drivers can save their efforts by replacing the 3 components at on time.
3. Enhanced Reliance. Clutch Kit includes all the clutch components including clutch cover, disc and bearing, customers can avoid any possible problem that could be caused by disharmony among parts manufactured by different makers.
If you have any questions, please contact with us directly. Welcome to visit our factory- SYC Clutch
Clutch Kit
Clutch Kit,Clutch Pressure Plate,Auto Clutch Kit,Clutch Disk
Yuhuan Shouyuan Machinery Co., Ltd. , http://www.sycclutch.com