Environmental Low Air Pressure Altitude and Temperature Test Lab Equipment
Model NO.: GATC-408
Loading Method: Dynamic Load
Display: Digital
Control: Computer Control
Weight: 100-500Kg
Power Source: AC380V
Oil Cylinder Position: Top
Cooling Rate: 0.7c~1.0c/Min (Average)
Pressure Range: RP~0.5kpa
Temp Fluctuation: +/-0.5%
Temp Range: 70c~+150c
Trademark: Grande
Transport Package: Strong Wood Case
Specification: 1100*1850*1700mm
Origin: China
HS Code: 9031200020
Product description:
High altitude low pressure simulation test chamber/Altitude test chamber
Altitude Test Chambers
Temperature testing at altitudes up to 100,000 feet.
Grande can provide custom-built chambers for simultaneous testing of temperature and low-pressure altitude conditions. Two common applications are:
- Testing of avionics or other aerospace equipment to simulate actual conditions it might experience.
- Simulation of high-altitude conditions like might be found in mountainous regions.
Features
- Temperature range from -70 to 200°C
- Altitude range from ground to 100,000 feet
- Optional humidity control when altitude system is off
- Chamber interior size specified by customer
-
Automatic altitude control, integrated with temperature controller
      -No manual setting of altitude level! - Vacuum pump sized for climb/dive rate required by application
- Viewing window and cable ports available
1.GB10590-89Â Low-temperature and low atmospheric pressure testing condition
2.GB10591-89 High-temperature and low atmospheric pressure testing condition
3. GB11159-89 low atmospheric pressure technical condition
4. GB/T2423.25-1992 Low-temperature and low atmospheric pressure test chamber
5. GB/T2423.26-1992Â High-temperature and low atmospheric pressure test chamber
6.GJB150.2-86Â High-temperature and low atmospheric pressure(Altitude) test
7,IEC60068-2-1.1990 Testing methods of Low-temperature test chambers
8,IEC60068-2-2.1974Â Testing methods of High-temperature test chambers
9,IEC-540
10,ASTM D2436
11,JIS K7212
12,DIN 50011
13,BS2648
14,Mil-Std 202G (conditions 105C, A/B/C/F)
15,Mil-Std 810G (condition 500.5)
16,IEC 60068-2-39
17,IEC 60068-2-40
18,RTCA/DO-160F
19,JIS W 0812
Â
Technical parameters:
Model No | GATC-150 | GATC-225 | GATC-408 | GATC-800 | GATC-1000 | |||||
Working room(L) | 150 | 225 | 408 | 800 | 1000 | |||||
Inner chamber size(mm)W*H*D | 500*600*500 | 500*750*600 | 600*850*800 | 1000*1000*800 | 1000*1000*1000 | |||||
Exterior chamber size(mm)W*H*D | 1000*1600*1400 | 1000*1750*1500 | 1100*1850*1700 | 1500*2000*1700 | 1850*1600*2250 | |||||
Packaging volume(CBM) | 3 | 3.5 | 4.5 | 5.5 | 6 | |||||
G.W.(KGs) | 320 | 350 | 400 | 600 | 700 | |||||
Testing temperature range | -80°C,-73°C,-60°C, -40°C, -20°C, 0°C~+150°C, +200°C (300°C) | |||||||||
Performance | Temperature range | -65ºC~150ºC | ||||||||
Temp.fluctuation | ±0.5ºC(Room pressure) | |||||||||
Temp.accuracy | ±2.0ºC(Room pressure) | |||||||||
Heating up time | ≤60min(+20ºC~+150ºC,RP,No-Load) | |||||||||
Cooling down time | ≤45min(RP) | ≤60min(RP) | ≤90min(RP) | |||||||
Pressure range | Â RP~0.5kPa | |||||||||
Pressure control tolerance | ±0.1kPa(≤2kPa),±5%(2kPa~40kPa),±2kPa(≥40kPa) | |||||||||
Depressurization time | ≤20min | ≤25min | ≤30min | ≤45min | ≤50min | |||||
Working environment | Temp:+5ºC~+35ºC;Humidity:≤90%RH;Airpressure:86-106kPa | |||||||||
Material | Exterior chamber materia | Stainless steel plate+ powder coated | ||||||||
Inner chamber materia | SUS#304 stainless steel plate | |||||||||
Insulation Material | PU Fiberglass wool | |||||||||
System | Air circulation system | Cooling fan | ||||||||
Heating System | SUS#304 stainless steel high-speed heater | |||||||||
Humidification system | Imported compressor,Tecumseh compressor(or Bizer Compressor),finned type evaporator,air(Water)-cooling condenser | |||||||||
Dehumidification system | ADP critical dew point cooling/dehumidifying method | |||||||||
Controlling system | TEMI880,990 | |||||||||
Power kw | 8 | 10 | 12 | 15 | 20 | |||||
Water supply | Water temperature:≤30ºC;water pressure:0.2~0.4MPa;flow rate:≥10T/h | |||||||||
Other components | Specimen holders 2pcs,electrical wire 1pc(3M),pressure testing port. | |||||||||
Safety protection device | Over-heat protection circuit breaker,Compressor overload protection,Control system overload protection,Humidifying system overload protection,Overload indicator lamp. | |||||||||
Power supply | AC 3Ψ380V 60/50Hz | |||||||||
Customized service | Welcome to Non-standard,Specail requirements,OEM/ODM orders. |
Â
Optional accessories1,Low Humidity and Dehumidifying sytstem.
2,Inner glass door with manual operating ports.
3,Temp./Humi.Recorder.
4,Pure water treatment device
5,RS-485 interface can be linked to Personal computer(PC) and achieve multi-level control & recording software management.
6,Liquid nitrogen(LN2)/Liquid Carbon Dioxide(LCO2) fast cooling-down system.
Perkins Kit,Fuel Filter,Oil Filter,Perkins Fuel Filter
JiLin LangYi Mechanical Equipment Company Ltd. , https://www.vxceo.com