Shanghai Shangchai 700kw/875kVA Diesel Generator Set Supplier
Model NO.: FM700GF
Conditions of Use: Land Use
Usage: Common Units, Standby Unit, Emergency Crew
Landuse Type of Unit: Ordinary
Excitation Mode: AC Rotating Exciter
Trademark: Foothills of weifang
Transport Package: The Wooden Case
Origin: China
HS Code: 8502120000
Model NO.: FM700GF
Conditions of Use: Land Use
Usage: Common Units, Standby Unit, Emergency Crew
Landuse Type of Unit: Ordinary
Excitation Mode: AC Rotating Exciter
Trademark: Foothills of weifang
Transport Package: The Wooden Case
Origin: China
HS Code: 8502120000
Company profile   Our company mainly produces and operates diesel generating sets, Marine diesel generating sets, clutch sets, water pump sets, mobile trailers, static speakers, automatic control cabinets, etc. Widely used in real estate, petroleum, communications, factories, highway and railway construction, industrial park, breeding industry, drilling machine, coal pulverizer and other industries.
Mainly choose brands
Diesel engines: weichai, shangchai, cummins, ji chai, perkins, daewoo, chang chai, tin chai, yangchai and other well-known brands at home and abroad.
Generator: Shanghai Stanford, guangzhou English and other well-known brands.
Years to provide quality factory accessories.
The main products
   Â
 Optional configuration
 1. Oil, diesel oil, water jacket, anti-condensation heater (water heater, oil heater);
2. Battery floating charger and self-starting unit control screen; Control screen of "three remote" function unit and ATS switch cabinet;
3. Separate daily fuel tank and integrated base fuel tank;
4. Silent type unit (box cabinet) and rainproof type unit (box cabinet);
5. Mobile towing vehicle power station (container trailer) and silent mobile power station (container trailer)Â
  Instructions for use of generator sets
    1. Use 0# ~ -30# light diesel oil for diesel oil; Oil of 15w-40cd (or as required by the diesel engine specification);
2, start temperature of + 5 ºC or more; Bring water when the oil temperature heating device, the start temperature of 15 ºC; The unit under 0 ºC, when using antifreeze and other low-temperature start measures should be adopted;
3. The company can provide not only 8kw-1000kw land-use units, but also Marine units of the same power range and various generating units of 60HZ 1800 RPM;
4. Users in cold areas: according to the temperature change, the oil, diesel and cooling fluid should be adjusted properly to ensure the normal operation of the unit;
5. As the product is constantly updated, if the sample parameters are changed or changed, the random documents shall prevail. The company has the right of final interpretation without prior notice;
6. The straight generator set is less than 1,000m above sea level and does not need correction power; Between 1000 and 3000 meters, the correction is 4% for every 500 meters up, and between 3000 and 5000 meters, the correction is 6% for every 500 meters up.
Safe use of diesel generator set
   Objective:
Strengthen the daily maintenance and maintenance of machinery, ensure the safety standard operation to quickly open the equipment in case of power failure, and ensure the normal operation of all electrical equipment.
1. Preparation before starting up
1.1 the water mark, oil mark, rust and other sundries of the attachment unit are clear and clean.
1.2 make a comprehensive inspection of each device of the unit, and check whether all connections, fastenings and operating parts have been firmly connected and appropriate. The nut of the cross-through shock absorber shall not be twisted too tightly, otherwise, the shock absorber will fail.
1.3 check whether the fuel storage in the fuel tank meets the requirements.
1.4 check whether the oil volume in the diesel oil sump, injection pump and governor is sufficient.
1.5 fill the water tank (radiator) with cooling water.
1.6 check all electrical parts. All contacts should be firm and correct. The automatic air switch should be in the disconnection position.
2. Startup steps
2.1 unscrew the vent screw on the fuel pump, remove the air in the fuel system with the fuel hand pump, and fix the adjusting control handle at the throttle position suitable for starting speed.
2.2 press the start button to start the diesel engine. If the diesel engine cannot start on fire for 10 seconds (up to 15 seconds), the engine should be started for a second time after 1 minute. If the engine fails to start for three consecutive times, the fault should be checked and found.
2.3 after the diesel engine starts, please pay close attention to the oil pressure gauge reading (2.5-3.5kg/Cm squared in normal operation). If the oil pressure gauge does not indicate, stop it immediately and check whether the ammeter has charging indication.
2.4 after the unit starts, the no-load speed gradually increases to 1000-1200r/min (note: do not operate for a long time). After the diesel engine preheats, the speed is raised to the rated speed. Stay out of the water temperature reaches 55 ° C, the oil temperature reaches 45 ° C, full load operation.
2.5 when the unit's instruments are normal, the load switch can be switched on to send power to the load. As the unit's load changes, if the frequency and voltage are not within the specified range, the frequency and voltage shall be adjusted in time to maintain the rating. It is strictly forbidden for the unit to carry load at low speed to avoid damage to the equipment.
2.6 after the unit is put into normal operation, it shall observe the changes of water temperature, oil temperature and oil pressure at any time, as well as the reading of power meter, frequency meter, ammeter and voltage meter, and timely deal with any abnormity found.
3. Stopping procedure
3.1 discharge the load gradually and disconnect the load switch.
In the no-load state of about 1000rpm, the diesel engine is allowed to run for several minutes. When the oil temperature and water temperature are significantly decreased, the engine will stop after adjusting the speed control handle to the position when the engine is first started, and finally remove the iron wire of the battery tower.
4. Maintenance procedures
4.1 check the charging battery, check the integrity of the battery, the relevant connection parts and the firmness of the screws.
4.2 check the integrity of the diesel container to prevent the container damage and leakage.
4.3 check the permeability of the smoke hole to prevent blockage due to long term shutdown and clean up.
 Â
 Company profile
   Our company mainly produces and operates diesel generating sets, Marine diesel generating sets, clutch sets, water pump sets, mobile trailers, static speakers, automatic control cabinets, etc. Widely used in real estate, petroleum, communications, factories, highway and railway construction, industrial park, breeding industry, drilling machine, coal pulverizer and other industries.
Mainly choose brands
Diesel engines: weichai, shangchai, cummins, ji chai, perkins, daewoo, chang chai, tin chai, yangchai and other well-known brands at home and abroad.
Generator: Shanghai Stanford, guangzhou English and other well-known brands.
Years to provide quality factory accessories.
The main products
   Â
 Optional configuration
 1. Oil, diesel oil, water jacket, anti-condensation heater (water heater, oil heater);
2. Battery floating charger and self-starting unit control screen; Control screen of "three remote" function unit and ATS switch cabinet;
3. Separate daily fuel tank and integrated base fuel tank;
4. Silent type unit (box cabinet) and rainproof type unit (box cabinet);
5. Mobile towing vehicle power station (container trailer) and silent mobile power station (container trailer)Â
  Instructions for use of generator sets
    1. Use 0# ~ -30# light diesel oil for diesel oil; Oil of 15w-40cd (or as required by the diesel engine specification);
2, start temperature of + 5 ºC or more; Bring water when the oil temperature heating device, the start temperature of 15 ºC; The unit under 0 ºC, when using antifreeze and other low-temperature start measures should be adopted;
3. The company can provide not only 8kw-1000kw land-use units, but also Marine units of the same power range and various generating units of 60HZ 1800 RPM;
4. Users in cold areas: according to the temperature change, the oil, diesel and cooling fluid should be adjusted properly to ensure the normal operation of the unit;
5. As the product is constantly updated, if the sample parameters are changed or changed, the random documents shall prevail. The company has the right of final interpretation without prior notice;
6. The straight generator set is less than 1,000m above sea level and does not need correction power; Between 1000 and 3000 meters, the correction is 4% for every 500 meters up, and between 3000 and 5000 meters, the correction is 6% for every 500 meters up.
Safe use of diesel generator set
   Objective:
Strengthen the daily maintenance and maintenance of machinery, ensure the safety standard operation to quickly open the equipment in case of power failure, and ensure the normal operation of all electrical equipment.
1. Preparation before starting up
1.1 the water mark, oil mark, rust and other sundries of the attachment unit are clear and clean.
1.2 make a comprehensive inspection of each device of the unit, and check whether all connections, fastenings and operating parts have been firmly connected and appropriate. The nut of the cross-through shock absorber shall not be twisted too tightly, otherwise, the shock absorber will fail.
1.3 check whether the fuel storage in the fuel tank meets the requirements.
1.4 check whether the oil volume in the diesel oil sump, injection pump and governor is sufficient.
1.5 fill the water tank (radiator) with cooling water.
1.6 check all electrical parts. All contacts should be firm and correct. The automatic air switch should be in the disconnection position.
2. Startup steps
2.1 unscrew the vent screw on the fuel pump, remove the air in the fuel system with the fuel hand pump, and fix the adjusting control handle at the throttle position suitable for starting speed.
2.2 press the start button to start the diesel engine. If the diesel engine cannot start on fire for 10 seconds (up to 15 seconds), the engine should be started for a second time after 1 minute. If the engine fails to start for three consecutive times, the fault should be checked and found.
2.3 after the diesel engine starts, please pay close attention to the oil pressure gauge reading (2.5-3.5kg/Cm squared in normal operation). If the oil pressure gauge does not indicate, stop it immediately and check whether the ammeter has charging indication.
2.4 after the unit starts, the no-load speed gradually increases to 1000-1200r/min (note: do not operate for a long time). After the diesel engine preheats, the speed is raised to the rated speed. Stay out of the water temperature reaches 55 ° C, the oil temperature reaches 45 ° C, full load operation.
2.5 when the unit's instruments are normal, the load switch can be switched on to send power to the load. As the unit's load changes, if the frequency and voltage are not within the specified range, the frequency and voltage shall be adjusted in time to maintain the rating. It is strictly forbidden for the unit to carry load at low speed to avoid damage to the equipment.
2.6 after the unit is put into normal operation, it shall observe the changes of water temperature, oil temperature and oil pressure at any time, as well as the reading of power meter, frequency meter, ammeter and voltage meter, and timely deal with any abnormity found.
3. Stopping procedure
3.1 discharge the load gradually and disconnect the load switch.
In the no-load state of about 1000rpm, the diesel engine is allowed to run for several minutes. When the oil temperature and water temperature are significantly decreased, the engine will stop after adjusting the speed control handle to the position when the engine is first started, and finally remove the iron wire of the battery tower.
4. Maintenance procedures
4.1 check the charging battery, check the integrity of the battery, the relevant connection parts and the firmness of the screws.
4.2 check the integrity of the diesel container to prevent the container damage and leakage.
4.3 check the permeability of the smoke hole to prevent blockage due to long term shutdown and clean up.
 Â
Â
Dental Equipment,Dental Lab Bench,Dental Work Bench
Head Screw,Hex Bolt,Blind Rivet Co., Ltd. , http://www.ejs-screw.com